电蒸汽锅炉供热系统如何调节?

电蒸汽锅炉点火运行前应对供热系统进行调节,下面济南盛鑫锅炉的有关技术人员就给大家介绍一下供热系统的调节方法。

1、电蒸汽锅炉加水,打开补水阀门,将锅炉注水至正常水位,然后关闭补水阀门。打开系统补水管阀门进行加水,并观察各自动排气情况,直到排气阀不排气为止,然后关闭加水阀门。
Electric steam boiler, add water, open water valves, boiler water to the normal water level, and then close the water valve. Open the system fill with water pipe valves and automatic exhaust situation observed until the exhaust vent is not far, and then close the valve with water.

2、电蒸汽锅炉与系统加完水后通过控制箱设定水泵低温运转,开泵前除加水阀门不开外所有阀门均开启,还应打开启闭器液压管排气阀排气。此时应观察锅炉水位,如水位上升,则应适当关小阻力调节阀,直到锅炉水位不升为止:如水位下降,证明系统水不满,应继续往锅炉补水,直到水位不降为止。
Electric steam boiler and system after adding water pump cryogenic operation by setting the control box, before adding water pump in addition to the valve does away all valves are open, but also opens the exhaust valve opening and closing hydraulic pipe exhaust. You should observe the boiler water level, such as the water level rises, off a small resistance should be appropriate to adjust the valve until the boiler water level does not rise so far: If the water level drops, water proof system discontent, should continue to boiler feed water, until the water level does not drop so far.

3、电蒸汽锅炉水位调整正常后,关闭水泵,检查启闭器,止回阀是否正常。检查的方法是看锅炉水位是否上升,如上升,证明有关闭不严的地方,可耳附在启闭器和止回阀上听,如关闭不严则会听到“嚓嚓”的水流声,如是启闭器的问题请按其说明书处理,如是启回阀的问题,应拆下检查活门是否灵活,阀里是否有异物卡住。
Electric steam boiler water level adjusted properly, turn off the pump, check the hoist, a check valve is normal. Way to check is to see if the boiler water level rises, such as rise, proved lax closed places, listening ear attached to the hoist and check valves, such as closed lax will hear "Cha Cha" sound of water , the case of the opening and closing its manual handling problems,please problems in the case of Kai-return valve, remove the check valves is flexible, if there is a valve in the foreign body stuck.

电蒸汽锅炉http://www.jnshengxin.cn/


下一篇:变频电热水锅炉采暖效果的有哪些影响因素?
上一篇:不同电锅炉的差别在哪里?

热门产品推荐